mac80211: Check pending scan request after having processed mgd work
authorJouni Malinen <jouni.malinen@atheros.com>
Tue, 25 Aug 2009 14:44:28 +0000 (17:44 +0300)
committerJohn W. Linville <linville@tuxdriver.com>
Fri, 28 Aug 2009 18:40:46 +0000 (14:40 -0400)
When the queued management work items are processed in
ieee80211_sta_work() an item could be removed. This could change the
anybusy from true to false, so we better check whether we can start a
new scan only after having processed the pending work first.

Signed-off-by: Jouni Malinen <jouni.malinen@atheros.com>
Acked-by: Johannes Berg <johannes@sipsolutions.net>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
net/mac80211/mlme.c

index c374d2d..97a278a 100644 (file)
@@ -2123,25 +2123,9 @@ static void ieee80211_sta_work(struct work_struct *work)
                }
        }
 
-       list_for_each_entry(wk, &ifmgd->work_list, list) {
-               if (wk->state != IEEE80211_MGD_STATE_IDLE) {
-                       anybusy = true;
-                       break;
-               }
-       }
 
        ieee80211_recalc_idle(local);
 
-       if (!anybusy) {
-               mutex_unlock(&ifmgd->mtx);
-
-               if (test_and_clear_bit(IEEE80211_STA_REQ_SCAN, &ifmgd->request))
-                       ieee80211_queue_delayed_work(&local->hw,
-                                                    &local->scan_work,
-                                                    round_jiffies_relative(0));
-               return;
-       }
-
        list_for_each_entry_safe(wk, tmp, &ifmgd->work_list, list) {
                if (time_is_after_jiffies(wk->timeout)) {
                        /*
@@ -2187,6 +2171,18 @@ static void ieee80211_sta_work(struct work_struct *work)
                }
        }
 
+       list_for_each_entry(wk, &ifmgd->work_list, list) {
+               if (wk->state != IEEE80211_MGD_STATE_IDLE) {
+                       anybusy = true;
+                       break;
+               }
+       }
+       if (!anybusy &&
+           test_and_clear_bit(IEEE80211_STA_REQ_SCAN, &ifmgd->request))
+               ieee80211_queue_delayed_work(&local->hw,
+                                            &local->scan_work,
+                                            round_jiffies_relative(0));
+
        mutex_unlock(&ifmgd->mtx);
 
        list_for_each_entry_safe(wk, tmp, &free_work, list) {