[SCSI] zfcp: Fix oops during shutdown of offline device
authorChristof Schmitt <christof.schmitt@de.ibm.com>
Thu, 24 Sep 2009 08:23:23 +0000 (10:23 +0200)
committerJames Bottomley <James.Bottomley@suse.de>
Fri, 2 Oct 2009 14:49:59 +0000 (09:49 -0500)
With the change that the zfcp_adapter struct is only allocated when
the device is set online, the shutdown handler has to check for a
non-existing zfcp_adapter struct. On the other hand, this check is not
necessary in the offline callback, since an online device has the
zfcp_adapter allocated and we go through the offline callback before
removing the ccw device.

Reviewed-by: Felix Beck <felix.beck@de.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
drivers/s390/scsi/zfcp_ccw.c

index ef5282d..95644b7 100644 (file)
@@ -192,13 +192,9 @@ static int zfcp_ccw_set_offline(struct ccw_device *ccw_device)
 
        mutex_lock(&zfcp_data.config_mutex);
        adapter = dev_get_drvdata(&ccw_device->dev);
-       if (!adapter)
-               goto out;
-
        zfcp_erp_adapter_shutdown(adapter, 0, "ccsoff1", NULL);
        zfcp_erp_wait(adapter);
        mutex_unlock(&zfcp_data.config_mutex);
-out:
        return 0;
 }
 
@@ -253,9 +249,13 @@ static void zfcp_ccw_shutdown(struct ccw_device *cdev)
 
        mutex_lock(&zfcp_data.config_mutex);
        adapter = dev_get_drvdata(&cdev->dev);
+       if (!adapter)
+               goto out;
+
        zfcp_erp_adapter_shutdown(adapter, 0, "ccshut1", NULL);
        zfcp_erp_wait(adapter);
        zfcp_erp_thread_kill(adapter);
+out:
        mutex_unlock(&zfcp_data.config_mutex);
 }