MIPS: MSP71xx: Resolve multiple definition of plat_timer_setup
authorShane McDonald <mcdonald.shane@gmail.com>
Tue, 28 Apr 2009 05:50:21 +0000 (23:50 -0600)
committerRalf Baechle <ralf@linux-mips.org>
Thu, 14 May 2009 12:50:28 +0000 (13:50 +0100)
There have been a number of compile problems with the msp71xx configuration
ever since it was included in the linux-mips.org repository.  This patch
resolves the "multiple definition of plat_timer_setup" problem, and creates
the required get_c0_compare_int function.

This patch has been compile-tested against the current HEAD.

Signed-off-by: Shane McDonald <mcdonald.shane@gmail.com>
Signed-off-by: Ralf Baechle <ralf@linux-mips.org>
arch/mips/pmc-sierra/msp71xx/msp_time.c

index 7cfeda5..cca64e1 100644 (file)
@@ -81,10 +81,7 @@ void __init plat_time_init(void)
        mips_hpt_frequency = cpu_rate/2;
 }
 
-void __init plat_timer_setup(struct irqaction *irq)
+unsigned int __init get_c0_compare_int(void)
 {
-#ifdef CONFIG_IRQ_MSP_CIC
-       /* we are using the vpe0 counter for timer interrupts */
-       setup_irq(MSP_INT_VPE0_TIMER, irq);
-#endif
+       return MSP_INT_VPE0_TIMER;
 }