[PATCH] USB: ftdi_sio: new microHAM and Evolution Robotics devices
[safe/jmp/linux-2.6] / drivers / usb / serial / ftdi_sio.h
1 /*
2  * Definitions for the FTDI USB Single Port Serial Converter - 
3  * known as FTDI_SIO (Serial Input/Output application of the chipset) 
4  *
5  * The example I have is known as the USC-1000 which is available from
6  * http://www.dse.co.nz - cat no XH4214 It looks similar to this:
7  * http://www.dansdata.com/usbser.htm but I can't be sure There are other
8  * USC-1000s which don't look like my device though so beware!
9  *
10  * The device is based on the FTDI FT8U100AX chip. It has a DB25 on one side, 
11  * USB on the other.
12  *
13  * Thanx to FTDI (http://www.ftdi.co.uk) for so kindly providing details
14  * of the protocol required to talk to the device and ongoing assistence
15  * during development.
16  *
17  * Bill Ryder - bryder@sgi.com formerly of Silicon Graphics, Inc.- wrote the 
18  * FTDI_SIO implementation.
19  *
20  * Philipp Gühring - pg@futureware.at - added the Device ID of the USB relais
21  * from Rudolf Gugler
22  *
23  */
24
25 #define FTDI_VID        0x0403  /* Vendor Id */
26 #define FTDI_SIO_PID    0x8372  /* Product Id SIO application of 8U100AX  */
27 #define FTDI_8U232AM_PID 0x6001 /* Similar device to SIO above */
28 #define FTDI_8U232AM_ALT_PID 0x6006 /* FTDI's alternate PID for above */
29 #define FTDI_8U2232C_PID 0x6010 /* Dual channel device */
30 #define FTDI_RELAIS_PID 0xFA10  /* Relais device from Rudolf Gugler */
31 #define FTDI_NF_RIC_VID 0x0DCD  /* Vendor Id */
32 #define FTDI_NF_RIC_PID 0x0001  /* Product Id */
33
34 /* www.irtrans.de device */
35 #define FTDI_IRTRANS_PID 0xFC60 /* Product Id */
36
37 /* www.crystalfontz.com devices - thanx for providing free devices for evaluation ! */
38 /* they use the ftdi chipset for the USB interface and the vendor id is the same */
39 #define FTDI_XF_632_PID 0xFC08  /* 632: 16x2 Character Display */
40 #define FTDI_XF_634_PID 0xFC09  /* 634: 20x4 Character Display */
41 #define FTDI_XF_547_PID 0xFC0A  /* 547: Two line Display */
42 #define FTDI_XF_633_PID 0xFC0B  /* 633: 16x2 Character Display with Keys */
43 #define FTDI_XF_631_PID 0xFC0C  /* 631: 20x2 Character Display */
44 #define FTDI_XF_635_PID 0xFC0D  /* 635: 20x4 Character Display */
45 #define FTDI_XF_640_PID 0xFC0E  /* 640: Two line Display */
46 #define FTDI_XF_642_PID 0xFC0F  /* 642: Two line Display */
47
48 /* Video Networks Limited / Homechoice in the UK use an ftdi-based device for their 1Mb */
49 /* broadband internet service.  The following PID is exhibited by the usb device supplied */
50 /* (the VID is the standard ftdi vid (FTDI_VID) */
51 #define FTDI_VNHCPCUSB_D_PID 0xfe38 /* Product Id */
52
53 /*
54  * The following are the values for the Matrix Orbital LCD displays,
55  * which are the FT232BM ( similar to the 8U232AM )
56  */
57 #define FTDI_MTXORB_0_PID      0xFA00  /* Matrix Orbital Product Id */
58 #define FTDI_MTXORB_1_PID      0xFA01  /* Matrix Orbital Product Id */
59 #define FTDI_MTXORB_2_PID      0xFA02  /* Matrix Orbital Product Id */
60 #define FTDI_MTXORB_3_PID      0xFA03  /* Matrix Orbital Product Id */
61 #define FTDI_MTXORB_4_PID      0xFA04  /* Matrix Orbital Product Id */
62 #define FTDI_MTXORB_5_PID      0xFA05  /* Matrix Orbital Product Id */
63 #define FTDI_MTXORB_6_PID      0xFA06  /* Matrix Orbital Product Id */
64
65 /* Interbiometrics USB I/O Board */
66 /* Developed for Interbiometrics by Rudolf Gugler */
67 #define INTERBIOMETRICS_VID              0x1209
68 #define INTERBIOMETRICS_IOBOARD_PID      0x1002
69 #define INTERBIOMETRICS_MINI_IOBOARD_PID 0x1006
70
71 /*
72  * The following are the values for the Perle Systems
73  * UltraPort USB serial converters
74  */
75 #define FTDI_PERLE_ULTRAPORT_PID 0xF0C0 /* Perle UltraPort Product Id */
76
77 /*
78  * The following are the values for the Sealevel SeaLINK+ adapters.
79  * (Original list sent by Tuan Hoang.  Ian Abbott renamed the macros and
80  * removed some PIDs that don't seem to match any existing products.)
81  */
82 #define SEALEVEL_VID            0x0c52  /* Sealevel Vendor ID */
83 #define SEALEVEL_2101_PID       0x2101  /* SeaLINK+232 (2101/2105) */
84 #define SEALEVEL_2102_PID       0x2102  /* SeaLINK+485 (2102) */
85 #define SEALEVEL_2103_PID       0x2103  /* SeaLINK+232I (2103) */
86 #define SEALEVEL_2104_PID       0x2104  /* SeaLINK+485I (2104) */
87 #define SEALEVEL_2201_1_PID     0x2211  /* SeaPORT+2/232 (2201) Port 1 */
88 #define SEALEVEL_2201_2_PID     0x2221  /* SeaPORT+2/232 (2201) Port 2 */
89 #define SEALEVEL_2202_1_PID     0x2212  /* SeaPORT+2/485 (2202) Port 1 */
90 #define SEALEVEL_2202_2_PID     0x2222  /* SeaPORT+2/485 (2202) Port 2 */
91 #define SEALEVEL_2203_1_PID     0x2213  /* SeaPORT+2 (2203) Port 1 */
92 #define SEALEVEL_2203_2_PID     0x2223  /* SeaPORT+2 (2203) Port 2 */
93 #define SEALEVEL_2401_1_PID     0x2411  /* SeaPORT+4/232 (2401) Port 1 */
94 #define SEALEVEL_2401_2_PID     0x2421  /* SeaPORT+4/232 (2401) Port 2 */
95 #define SEALEVEL_2401_3_PID     0x2431  /* SeaPORT+4/232 (2401) Port 3 */
96 #define SEALEVEL_2401_4_PID     0x2441  /* SeaPORT+4/232 (2401) Port 4 */
97 #define SEALEVEL_2402_1_PID     0x2412  /* SeaPORT+4/485 (2402) Port 1 */
98 #define SEALEVEL_2402_2_PID     0x2422  /* SeaPORT+4/485 (2402) Port 2 */
99 #define SEALEVEL_2402_3_PID     0x2432  /* SeaPORT+4/485 (2402) Port 3 */
100 #define SEALEVEL_2402_4_PID     0x2442  /* SeaPORT+4/485 (2402) Port 4 */
101 #define SEALEVEL_2403_1_PID     0x2413  /* SeaPORT+4 (2403) Port 1 */
102 #define SEALEVEL_2403_2_PID     0x2423  /* SeaPORT+4 (2403) Port 2 */
103 #define SEALEVEL_2403_3_PID     0x2433  /* SeaPORT+4 (2403) Port 3 */
104 #define SEALEVEL_2403_4_PID     0x2443  /* SeaPORT+4 (2403) Port 4 */
105 #define SEALEVEL_2801_1_PID     0X2811  /* SeaLINK+8/232 (2801) Port 1 */
106 #define SEALEVEL_2801_2_PID     0X2821  /* SeaLINK+8/232 (2801) Port 2 */
107 #define SEALEVEL_2801_3_PID     0X2831  /* SeaLINK+8/232 (2801) Port 3 */
108 #define SEALEVEL_2801_4_PID     0X2841  /* SeaLINK+8/232 (2801) Port 4 */
109 #define SEALEVEL_2801_5_PID     0X2851  /* SeaLINK+8/232 (2801) Port 5 */
110 #define SEALEVEL_2801_6_PID     0X2861  /* SeaLINK+8/232 (2801) Port 6 */
111 #define SEALEVEL_2801_7_PID     0X2871  /* SeaLINK+8/232 (2801) Port 7 */
112 #define SEALEVEL_2801_8_PID     0X2881  /* SeaLINK+8/232 (2801) Port 8 */
113 #define SEALEVEL_2802_1_PID     0X2812  /* SeaLINK+8/485 (2802) Port 1 */
114 #define SEALEVEL_2802_2_PID     0X2822  /* SeaLINK+8/485 (2802) Port 2 */
115 #define SEALEVEL_2802_3_PID     0X2832  /* SeaLINK+8/485 (2802) Port 3 */
116 #define SEALEVEL_2802_4_PID     0X2842  /* SeaLINK+8/485 (2802) Port 4 */
117 #define SEALEVEL_2802_5_PID     0X2852  /* SeaLINK+8/485 (2802) Port 5 */
118 #define SEALEVEL_2802_6_PID     0X2862  /* SeaLINK+8/485 (2802) Port 6 */
119 #define SEALEVEL_2802_7_PID     0X2872  /* SeaLINK+8/485 (2802) Port 7 */
120 #define SEALEVEL_2802_8_PID     0X2882  /* SeaLINK+8/485 (2802) Port 8 */
121 #define SEALEVEL_2803_1_PID     0X2813  /* SeaLINK+8 (2803) Port 1 */
122 #define SEALEVEL_2803_2_PID     0X2823  /* SeaLINK+8 (2803) Port 2 */
123 #define SEALEVEL_2803_3_PID     0X2833  /* SeaLINK+8 (2803) Port 3 */
124 #define SEALEVEL_2803_4_PID     0X2843  /* SeaLINK+8 (2803) Port 4 */
125 #define SEALEVEL_2803_5_PID     0X2853  /* SeaLINK+8 (2803) Port 5 */
126 #define SEALEVEL_2803_6_PID     0X2863  /* SeaLINK+8 (2803) Port 6 */
127 #define SEALEVEL_2803_7_PID     0X2873  /* SeaLINK+8 (2803) Port 7 */
128 #define SEALEVEL_2803_8_PID     0X2883  /* SeaLINK+8 (2803) Port 8 */
129
130 /*
131  * DSS-20 Sync Station for Sony Ericsson P800
132  */
133  
134 #define FTDI_DSS20_PID          0xFC82  
135
136 /*
137  * Home Electronics (www.home-electro.com) USB gadgets
138  */
139 #define FTDI_HE_TIRA1_PID       0xFA78  /* Tira-1 IR transceiver */
140
141 /* USB-UIRT - An infrared receiver and transmitter using the 8U232AM chip */
142 /* http://home.earthlink.net/~jrhees/USBUIRT/index.htm */
143 #define FTDI_USB_UIRT_PID       0xF850  /* Product Id */
144
145 /* ELV USB Module UO100 (PID sent by Stefan Frings) */
146 #define FTDI_ELV_UO100_PID      0xFB58  /* Product Id */
147 /* ELV USB Module UM100 (PID sent by Arnim Laeuger) */
148 #define FTDI_ELV_UM100_PID      0xFB5A  /* Product Id */
149
150 /*
151  * Definitions for ID TECH (www.idt-net.com) devices
152  */
153 #define IDTECH_VID              0x0ACD  /* ID TECH Vendor ID */
154 #define IDTECH_IDT1221U_PID     0x0300  /* IDT1221U USB to RS-232 adapter */
155
156 /*
157  * Definitions for Omnidirectional Control Technology, Inc. devices
158  */
159 #define OCT_VID                 0x0B39  /* OCT vendor ID */
160 /* Note: OCT US101 is also rebadged as Dick Smith Electronics (NZ) XH6381 */
161 /* Also rebadged as Dick Smith Electronics (Aus) XH6451 */
162 /* Also rebadged as SIIG Inc. model US2308 hardware version 1 */
163 #define OCT_US101_PID           0x0421  /* OCT US101 USB to RS-232 */
164
165 /* an infrared receiver for user access control with IR tags */
166 #define FTDI_PIEGROUP_PID       0xF208  /* Product Id */
167
168 /*
169  * Protego product ids
170  */
171 #define PROTEGO_SPECIAL_1       0xFC70  /* special/unknown device */
172 #define PROTEGO_R2X0            0xFC71  /* R200-USB TRNG unit (R210, R220, and R230) */
173 #define PROTEGO_SPECIAL_3       0xFC72  /* special/unknown device */
174 #define PROTEGO_SPECIAL_4       0xFC73  /* special/unknown device */
175
176 /*
177  * Gude Analog- und Digitalsysteme GmbH
178  */
179 #define FTDI_GUDEADS_E808_PID    0xE808
180 #define FTDI_GUDEADS_E809_PID    0xE809
181 #define FTDI_GUDEADS_E80A_PID    0xE80A
182 #define FTDI_GUDEADS_E80B_PID    0xE80B
183 #define FTDI_GUDEADS_E80C_PID    0xE80C
184 #define FTDI_GUDEADS_E80D_PID    0xE80D
185 #define FTDI_GUDEADS_E80E_PID    0xE80E
186 #define FTDI_GUDEADS_E80F_PID    0xE80F
187 #define FTDI_GUDEADS_E888_PID    0xE888  /* Expert ISDN Control USB */
188 #define FTDI_GUDEADS_E889_PID    0xE889  /* USB RS-232 OptoBridge */
189 #define FTDI_GUDEADS_E88A_PID    0xE88A
190 #define FTDI_GUDEADS_E88B_PID    0xE88B
191 #define FTDI_GUDEADS_E88C_PID    0xE88C
192 #define FTDI_GUDEADS_E88D_PID    0xE88D
193 #define FTDI_GUDEADS_E88E_PID    0xE88E
194 #define FTDI_GUDEADS_E88F_PID    0xE88F
195
196 /*
197  * Linx Technologies product ids
198  */
199 #define LINX_SDMUSBQSS_PID      0xF448  /* Linx SDM-USB-QS-S */
200 #define LINX_MASTERDEVEL2_PID   0xF449   /* Linx Master Development 2.0 */
201 #define LINX_FUTURE_0_PID   0xF44A   /* Linx future device */
202 #define LINX_FUTURE_1_PID   0xF44B   /* Linx future device */
203 #define LINX_FUTURE_2_PID   0xF44C   /* Linx future device */
204
205 /* CCS Inc. ICDU/ICDU40 product ID - the FT232BM is used in an in-circuit-debugger */
206 /* unit for PIC16's/PIC18's */
207 #define FTDI_CCSICDU20_0_PID    0xF9D0     
208 #define FTDI_CCSICDU40_1_PID    0xF9D1     
209
210 /* Inside Accesso contactless reader (http://www.insidefr.com) */
211 #define INSIDE_ACCESSO          0xFAD0
212
213 /*
214  * Intrepid Control Systems (http://www.intrepidcs.com/) ValueCAN and NeoVI
215  */
216 #define INTREPID_VID            0x093C
217 #define INTREPID_VALUECAN_PID   0x0601
218 #define INTREPID_NEOVI_PID      0x0701
219
220 /*
221  * Falcom Wireless Communications GmbH
222  */
223 #define FALCOM_VID              0x0F94  /* Vendor Id */
224 #define FALCOM_TWIST_PID        0x0001  /* Falcom Twist USB GPRS modem */
225
226 /*
227  * SUUNTO product ids
228  */
229 #define FTDI_SUUNTO_SPORTS_PID  0xF680  /* Suunto Sports instrument */
230
231 /*
232  * Definitions for B&B Electronics products.
233  */
234 #define BANDB_VID               0x0856  /* B&B Electronics Vendor ID */
235 #define BANDB_USOTL4_PID        0xAC01  /* USOTL4 Isolated RS-485 Converter */
236 #define BANDB_USTL4_PID         0xAC02  /* USTL4 RS-485 Converter */
237 #define BANDB_USO9ML2_PID       0xAC03  /* USO9ML2 Isolated RS-232 Converter */
238
239 /*
240  * RM Michaelides CANview USB (http://www.rmcan.com)
241  * CAN fieldbus interface adapter, added by port GmbH www.port.de)
242  * Ian Abbott changed the macro names for consistency.
243  */
244 #define FTDI_RM_CANVIEW_PID     0xfd60  /* Product Id */
245
246 /*
247  * EVER Eco Pro UPS (http://www.ever.com.pl/)
248  */
249
250 #define EVER_ECO_PRO_CDS        0xe520  /* RS-232 converter */
251
252 /*
253  * 4N-GALAXY.DE PIDs for CAN-USB, USB-RS232, USB-RS422, USB-RS485,
254  * USB-TTY activ, USB-TTY passiv.  Some PIDs are used by several devices
255  * and I'm not entirely sure which are used by which.
256  */
257 #define FTDI_4N_GALAXY_DE_0_PID 0x8372
258 #define FTDI_4N_GALAXY_DE_1_PID 0xF3C0
259 #define FTDI_4N_GALAXY_DE_2_PID 0xF3C1
260
261 /*
262  * Mobility Electronics products.
263  */
264 #define MOBILITY_VID                    0x1342
265 #define MOBILITY_USB_SERIAL_PID         0x0202  /* EasiDock USB 200 serial */
266
267 /*
268  * microHAM product IDs (http://www.microham.com).
269  * Submitted by Justin Burket (KL1RL) <zorton@jtan.com>.
270  */
271 #define FTDI_MHAM_Y6_PID 0xEEEA         /* USB-Y6 interface */
272 #define FTDI_MHAM_Y8_PID 0xEEEB         /* USB-Y8 interface */
273
274 /*
275  * Active Robots product ids.
276  */
277 #define FTDI_ACTIVE_ROBOTS_PID  0xE548  /* USB comms board */
278
279 /*
280  * Evolution Robotics products (http://www.evolution.com/).
281  * Submitted by Shawn M. Lavelle.
282  */
283 #define EVOLUTION_VID           0xDEEE  /* Vendor ID */
284 #define EVOLUTION_ER1_PID       0x0300  /* ER1 Control Module */
285
286 /* Commands */
287 #define FTDI_SIO_RESET          0 /* Reset the port */
288 #define FTDI_SIO_MODEM_CTRL     1 /* Set the modem control register */
289 #define FTDI_SIO_SET_FLOW_CTRL  2 /* Set flow control register */
290 #define FTDI_SIO_SET_BAUD_RATE  3 /* Set baud rate */
291 #define FTDI_SIO_SET_DATA       4 /* Set the data characteristics of the port */
292 #define FTDI_SIO_GET_MODEM_STATUS       5 /* Retrieve current value of modern status register */
293 #define FTDI_SIO_SET_EVENT_CHAR 6 /* Set the event character */
294 #define FTDI_SIO_SET_ERROR_CHAR 7 /* Set the error character */
295 #define FTDI_SIO_SET_LATENCY_TIMER      9 /* Set the latency timer */
296 #define FTDI_SIO_GET_LATENCY_TIMER      10 /* Get the latency timer */
297
298
299 /*
300  *   BmRequestType:  1100 0000b
301  *   bRequest:       FTDI_E2_READ
302  *   wValue:         0
303  *   wIndex:         Address of word to read
304  *   wLength:        2
305  *   Data:           Will return a word of data from E2Address
306  *
307  */
308
309 /* Port Identifier Table */
310 #define PIT_DEFAULT             0 /* SIOA */
311 #define PIT_SIOA                1 /* SIOA */
312 /* The device this driver is tested with one has only one port */
313 #define PIT_SIOB                2 /* SIOB */
314 #define PIT_PARALLEL            3 /* Parallel */
315
316 /* FTDI_SIO_RESET */
317 #define FTDI_SIO_RESET_REQUEST FTDI_SIO_RESET
318 #define FTDI_SIO_RESET_REQUEST_TYPE 0x40
319 #define FTDI_SIO_RESET_SIO 0
320 #define FTDI_SIO_RESET_PURGE_RX 1
321 #define FTDI_SIO_RESET_PURGE_TX 2
322
323 /*
324  * BmRequestType:  0100 0000B
325  * bRequest:       FTDI_SIO_RESET
326  * wValue:         Control Value 
327  *                   0 = Reset SIO
328  *                   1 = Purge RX buffer
329  *                   2 = Purge TX buffer
330  * wIndex:         Port
331  * wLength:        0
332  * Data:           None
333  *
334  * The Reset SIO command has this effect:
335  *
336  *    Sets flow control set to 'none'
337  *    Event char = $0D
338  *    Event trigger = disabled
339  *    Purge RX buffer
340  *    Purge TX buffer
341  *    Clear DTR
342  *    Clear RTS
343  *    baud and data format not reset
344  *
345  * The Purge RX and TX buffer commands affect nothing except the buffers
346  *
347    */
348
349 /* FTDI_SIO_SET_BAUDRATE */
350 #define FTDI_SIO_SET_BAUDRATE_REQUEST_TYPE 0x40
351 #define FTDI_SIO_SET_BAUDRATE_REQUEST 3
352
353 /*
354  * BmRequestType:  0100 0000B
355  * bRequest:       FTDI_SIO_SET_BAUDRATE
356  * wValue:         BaudDivisor value - see below
357  * wIndex:         Port
358  * wLength:        0
359  * Data:           None
360  * The BaudDivisor values are calculated as follows:
361  * - BaseClock is either 12000000 or 48000000 depending on the device. FIXME: I wish
362  *   I knew how to detect old chips to select proper base clock!
363  * - BaudDivisor is a fixed point number encoded in a funny way.
364  *   (--WRONG WAY OF THINKING--)
365  *   BaudDivisor is a fixed point number encoded with following bit weighs:
366  *   (-2)(-1)(13..0). It is a radical with a denominator of 4, so values
367  *   end with 0.0 (00...), 0.25 (10...), 0.5 (01...), and 0.75 (11...).
368  *   (--THE REALITY--)
369  *   The both-bits-set has quite different meaning from 0.75 - the chip designers
370  *   have decided it to mean 0.125 instead of 0.75.
371  *   This info looked up in FTDI application note "FT8U232 DEVICES \ Data Rates
372  *   and Flow Control Consideration for USB to RS232".
373  * - BaudDivisor = (BaseClock / 16) / BaudRate, where the (=) operation should
374  *   automagically re-encode the resulting value to take fractions into consideration.
375  * As all values are integers, some bit twiddling is in order:
376  *   BaudDivisor = (BaseClock / 16 / BaudRate) |
377  *   (((BaseClock / 2 / BaudRate) & 4) ? 0x4000    // 0.5
378  *    : ((BaseClock / 2 / BaudRate) & 2) ? 0x8000  // 0.25
379  *    : ((BaseClock / 2 / BaudRate) & 1) ? 0xc000  // 0.125
380  *    : 0)
381  *
382  * For the FT232BM, a 17th divisor bit was introduced to encode the multiples
383  * of 0.125 missing from the FT8U232AM.  Bits 16 to 14 are coded as follows
384  * (the first four codes are the same as for the FT8U232AM, where bit 16 is
385  * always 0):
386  *   000 - add .000 to divisor
387  *   001 - add .500 to divisor
388  *   010 - add .250 to divisor
389  *   011 - add .125 to divisor
390  *   100 - add .375 to divisor
391  *   101 - add .625 to divisor
392  *   110 - add .750 to divisor
393  *   111 - add .875 to divisor
394  * Bits 15 to 0 of the 17-bit divisor are placed in the urb value.  Bit 16 is 
395  * placed in bit 0 of the urb index.
396  *
397  * Note that there are a couple of special cases to support the highest baud
398  * rates.  If the calculated divisor value is 1, this needs to be replaced with
399  * 0.  Additionally for the FT232BM, if the calculated divisor value is 0x4001
400  * (1.5), this needs to be replaced with 0x0001 (1) (but this divisor value is
401  * not supported by the FT8U232AM).
402  */
403
404 typedef enum {
405         SIO = 1,
406         FT8U232AM = 2,
407         FT232BM = 3,
408         FT2232C = 4,
409 } ftdi_chip_type_t;
410
411 typedef enum {
412  ftdi_sio_b300 = 0, 
413  ftdi_sio_b600 = 1, 
414  ftdi_sio_b1200 = 2,
415  ftdi_sio_b2400 = 3,
416  ftdi_sio_b4800 = 4,
417  ftdi_sio_b9600 = 5,
418  ftdi_sio_b19200 = 6,
419  ftdi_sio_b38400 = 7,
420  ftdi_sio_b57600 = 8,
421  ftdi_sio_b115200 = 9
422 } FTDI_SIO_baudrate_t ;
423
424 /*
425  * The ftdi_8U232AM_xxMHz_byyy constants have been removed. The encoded divisor values
426  * are calculated internally.
427  */
428
429 #define FTDI_SIO_SET_DATA_REQUEST FTDI_SIO_SET_DATA
430 #define FTDI_SIO_SET_DATA_REQUEST_TYPE 0x40
431 #define FTDI_SIO_SET_DATA_PARITY_NONE (0x0 << 8 )
432 #define FTDI_SIO_SET_DATA_PARITY_ODD (0x1 << 8 )
433 #define FTDI_SIO_SET_DATA_PARITY_EVEN (0x2 << 8 )
434 #define FTDI_SIO_SET_DATA_PARITY_MARK (0x3 << 8 )
435 #define FTDI_SIO_SET_DATA_PARITY_SPACE (0x4 << 8 )
436 #define FTDI_SIO_SET_DATA_STOP_BITS_1 (0x0 << 11 )
437 #define FTDI_SIO_SET_DATA_STOP_BITS_15 (0x1 << 11 )
438 #define FTDI_SIO_SET_DATA_STOP_BITS_2 (0x2 << 11 )
439 #define FTDI_SIO_SET_BREAK (0x1 << 14)
440 /* FTDI_SIO_SET_DATA */
441
442 /*
443  * BmRequestType:  0100 0000B 
444  * bRequest:       FTDI_SIO_SET_DATA
445  * wValue:         Data characteristics (see below)
446  * wIndex:         Port
447  * wLength:        0
448  * Data:           No
449  *
450  * Data characteristics
451  *
452  *   B0..7   Number of data bits
453  *   B8..10  Parity
454  *           0 = None
455  *           1 = Odd
456  *           2 = Even
457  *           3 = Mark
458  *           4 = Space
459  *   B11..13 Stop Bits
460  *           0 = 1
461  *           1 = 1.5
462  *           2 = 2
463  *   B14
464  *           1 = TX ON (break)
465  *           0 = TX OFF (normal state)
466  *   B15 Reserved
467  *
468  */
469
470
471
472 /* FTDI_SIO_MODEM_CTRL */
473 #define FTDI_SIO_SET_MODEM_CTRL_REQUEST_TYPE 0x40
474 #define FTDI_SIO_SET_MODEM_CTRL_REQUEST FTDI_SIO_MODEM_CTRL
475
476 /* 
477  * BmRequestType:   0100 0000B
478  * bRequest:        FTDI_SIO_MODEM_CTRL
479  * wValue:          ControlValue (see below)
480  * wIndex:          Port
481  * wLength:         0
482  * Data:            None
483  *
484  * NOTE: If the device is in RTS/CTS flow control, the RTS set by this
485  * command will be IGNORED without an error being returned
486  * Also - you can not set DTR and RTS with one control message
487  */
488
489 #define FTDI_SIO_SET_DTR_MASK 0x1
490 #define FTDI_SIO_SET_DTR_HIGH ( 1 | ( FTDI_SIO_SET_DTR_MASK  << 8))
491 #define FTDI_SIO_SET_DTR_LOW  ( 0 | ( FTDI_SIO_SET_DTR_MASK  << 8))
492 #define FTDI_SIO_SET_RTS_MASK 0x2
493 #define FTDI_SIO_SET_RTS_HIGH ( 2 | ( FTDI_SIO_SET_RTS_MASK << 8 ))
494 #define FTDI_SIO_SET_RTS_LOW ( 0 | ( FTDI_SIO_SET_RTS_MASK << 8 ))
495
496 /*
497  * ControlValue
498  * B0    DTR state
499  *          0 = reset
500  *          1 = set
501  * B1    RTS state
502  *          0 = reset
503  *          1 = set
504  * B2..7 Reserved
505  * B8    DTR state enable
506  *          0 = ignore
507  *          1 = use DTR state
508  * B9    RTS state enable
509  *          0 = ignore
510  *          1 = use RTS state
511  * B10..15 Reserved
512  */
513
514 /* FTDI_SIO_SET_FLOW_CTRL */
515 #define FTDI_SIO_SET_FLOW_CTRL_REQUEST_TYPE 0x40
516 #define FTDI_SIO_SET_FLOW_CTRL_REQUEST FTDI_SIO_SET_FLOW_CTRL
517 #define FTDI_SIO_DISABLE_FLOW_CTRL 0x0 
518 #define FTDI_SIO_RTS_CTS_HS (0x1 << 8)
519 #define FTDI_SIO_DTR_DSR_HS (0x2 << 8)
520 #define FTDI_SIO_XON_XOFF_HS (0x4 << 8)
521 /*
522  *   BmRequestType:  0100 0000b
523  *   bRequest:       FTDI_SIO_SET_FLOW_CTRL
524  *   wValue:         Xoff/Xon
525  *   wIndex:         Protocol/Port - hIndex is protocl / lIndex is port
526  *   wLength:        0 
527  *   Data:           None
528  *
529  * hIndex protocol is:
530  *   B0 Output handshaking using RTS/CTS
531  *       0 = disabled
532  *       1 = enabled
533  *   B1 Output handshaking using DTR/DSR
534  *       0 = disabled
535  *       1 = enabled
536  *   B2 Xon/Xoff handshaking
537  *       0 = disabled
538  *       1 = enabled
539  *
540  * A value of zero in the hIndex field disables handshaking
541  *
542  * If Xon/Xoff handshaking is specified, the hValue field should contain the XOFF character 
543  * and the lValue field contains the XON character.
544  */  
545  
546 /*
547  * FTDI_SIO_GET_LATENCY_TIMER
548  *
549  * Set the timeout interval. The FTDI collects data from the slave
550  * device, transmitting it to the host when either A) 62 bytes are
551  * received, or B) the timeout interval has elapsed and the buffer
552  * contains at least 1 byte.  Setting this value to a small number
553  * can dramatically improve performance for applications which send
554  * small packets, since the default value is 16ms.
555  */
556 #define  FTDI_SIO_GET_LATENCY_TIMER_REQUEST FTDI_SIO_GET_LATENCY_TIMER
557 #define  FTDI_SIO_GET_LATENCY_TIMER_REQUEST_TYPE 0xC0
558
559 /* 
560  *  BmRequestType:   1100 0000b
561  *  bRequest:        FTDI_SIO_GET_LATENCY_TIMER
562  *  wValue:          0
563  *  wIndex:          Port
564  *  wLength:         0
565  *  Data:            latency (on return)
566  */
567
568 /* 
569  * FTDI_SIO_SET_LATENCY_TIMER
570  *
571  * Set the timeout interval. The FTDI collects data from the slave
572  * device, transmitting it to the host when either A) 62 bytes are
573  * received, or B) the timeout interval has elapsed and the buffer
574  * contains at least 1 byte.  Setting this value to a small number
575  * can dramatically improve performance for applications which send
576  * small packets, since the default value is 16ms.
577  */
578 #define  FTDI_SIO_SET_LATENCY_TIMER_REQUEST FTDI_SIO_SET_LATENCY_TIMER
579 #define  FTDI_SIO_SET_LATENCY_TIMER_REQUEST_TYPE 0x40
580
581 /* 
582  *  BmRequestType:   0100 0000b
583  *  bRequest:        FTDI_SIO_SET_LATENCY_TIMER
584  *  wValue:          Latency (milliseconds)
585  *  wIndex:          Port
586  *  wLength:         0
587  *  Data:            None
588  *
589  * wValue:
590  *   B0..7   Latency timer
591  *   B8..15  0
592  *
593  */
594
595 /*
596  * FTDI_SIO_SET_EVENT_CHAR 
597  *
598  * Set the special event character for the specified communications port.
599  * If the device sees this character it will immediately return the
600  * data read so far - rather than wait 40ms or until 62 bytes are read
601  * which is what normally happens.
602  */
603
604
605 #define  FTDI_SIO_SET_EVENT_CHAR_REQUEST FTDI_SIO_SET_EVENT_CHAR
606 #define  FTDI_SIO_SET_EVENT_CHAR_REQUEST_TYPE 0x40
607
608
609 /* 
610  *  BmRequestType:   0100 0000b
611  *  bRequest:        FTDI_SIO_SET_EVENT_CHAR
612  *  wValue:          EventChar
613  *  wIndex:          Port
614  *  wLength:         0
615  *  Data:            None
616  *
617  * wValue:
618  *   B0..7   Event Character
619  *   B8      Event Character Processing
620  *             0 = disabled
621  *             1 = enabled
622  *   B9..15  Reserved
623  *
624  */
625           
626 /* FTDI_SIO_SET_ERROR_CHAR */
627
628 /* Set the parity error replacement character for the specified communications port */
629
630 /* 
631  *  BmRequestType:  0100 0000b
632  *  bRequest:       FTDI_SIO_SET_EVENT_CHAR
633  *  wValue:         Error Char
634  *  wIndex:         Port
635  *  wLength:        0
636  *  Data:           None
637  *
638  *Error Char
639  *  B0..7  Error Character
640  *  B8     Error Character Processing
641  *           0 = disabled
642  *           1 = enabled
643  *  B9..15 Reserved
644  *
645  */
646
647 /* FTDI_SIO_GET_MODEM_STATUS */
648 /* Retreive the current value of the modem status register */
649
650 #define FTDI_SIO_GET_MODEM_STATUS_REQUEST_TYPE 0xc0
651 #define FTDI_SIO_GET_MODEM_STATUS_REQUEST FTDI_SIO_GET_MODEM_STATUS
652 #define FTDI_SIO_CTS_MASK 0x10
653 #define FTDI_SIO_DSR_MASK 0x20
654 #define FTDI_SIO_RI_MASK  0x40
655 #define FTDI_SIO_RLSD_MASK 0x80
656 /* 
657  *   BmRequestType:   1100 0000b
658  *   bRequest:        FTDI_SIO_GET_MODEM_STATUS
659  *   wValue:          zero
660  *   wIndex:          Port
661  *   wLength:         1
662  *   Data:            Status
663  * 
664  * One byte of data is returned 
665  * B0..3 0
666  * B4    CTS
667  *         0 = inactive
668  *         1 = active
669  * B5    DSR
670  *         0 = inactive
671  *         1 = active
672  * B6    Ring Indicator (RI)
673  *         0 = inactive
674  *         1 = active
675  * B7    Receive Line Signal Detect (RLSD)
676  *         0 = inactive
677  *         1 = active 
678  */
679
680
681
682 /* Descriptors returned by the device 
683  * 
684  *  Device Descriptor
685  * 
686  * Offset       Field           Size    Value   Description
687  * 0    bLength         1       0x12    Size of descriptor in bytes
688  * 1    bDescriptorType 1       0x01    DEVICE Descriptor Type
689  * 2    bcdUSB          2       0x0110  USB Spec Release Number
690  * 4    bDeviceClass    1       0x00    Class Code
691  * 5    bDeviceSubClass 1       0x00    SubClass Code
692  * 6    bDeviceProtocol 1       0x00    Protocol Code
693  * 7    bMaxPacketSize0 1       0x08    Maximum packet size for endpoint 0
694  * 8    idVendor        2       0x0403  Vendor ID
695  * 10   idProduct       2       0x8372  Product ID (FTDI_SIO_PID)
696  * 12   bcdDevice       2       0x0001  Device release number
697  * 14   iManufacturer   1       0x01    Index of man. string desc
698  * 15   iProduct        1       0x02    Index of prod string desc
699  * 16   iSerialNumber   1       0x02    Index of serial nmr string desc
700  * 17   bNumConfigurations 1    0x01    Number of possible configurations
701  * 
702  * Configuration Descriptor
703  * 
704  * Offset       Field                   Size    Value
705  * 0    bLength                 1       0x09    Size of descriptor in bytes
706  * 1    bDescriptorType         1       0x02    CONFIGURATION Descriptor Type
707  * 2    wTotalLength            2       0x0020  Total length of data
708  * 4    bNumInterfaces          1       0x01    Number of interfaces supported
709  * 5    bConfigurationValue     1       0x01    Argument for SetCOnfiguration() req
710  * 6    iConfiguration          1       0x02    Index of config string descriptor
711  * 7    bmAttributes            1       0x20    Config characteristics Remote Wakeup
712  * 8    MaxPower                1       0x1E    Max power consumption
713  * 
714  * Interface Descriptor
715  * 
716  * Offset       Field                   Size    Value
717  * 0    bLength                 1       0x09    Size of descriptor in bytes
718  * 1    bDescriptorType         1       0x04    INTERFACE Descriptor Type
719  * 2    bInterfaceNumber        1       0x00    Number of interface
720  * 3    bAlternateSetting       1       0x00    Value used to select alternate
721  * 4    bNumEndpoints           1       0x02    Number of endpoints
722  * 5    bInterfaceClass         1       0xFF    Class Code
723  * 6    bInterfaceSubClass      1       0xFF    Subclass Code
724  * 7    bInterfaceProtocol      1       0xFF    Protocol Code
725  * 8    iInterface              1       0x02    Index of interface string description
726  * 
727  * IN Endpoint Descriptor
728  * 
729  * Offset       Field                   Size    Value
730  * 0    bLength                 1       0x07    Size of descriptor in bytes
731  * 1    bDescriptorType         1       0x05    ENDPOINT descriptor type
732  * 2    bEndpointAddress        1       0x82    Address of endpoint
733  * 3    bmAttributes            1       0x02    Endpoint attributes - Bulk
734  * 4    bNumEndpoints           2       0x0040  maximum packet size
735  * 5    bInterval               1       0x00    Interval for polling endpoint
736  * 
737  * OUT Endpoint Descriptor
738  * 
739  * Offset       Field                   Size    Value
740  * 0    bLength                 1       0x07    Size of descriptor in bytes
741  * 1    bDescriptorType         1       0x05    ENDPOINT descriptor type
742  * 2    bEndpointAddress        1       0x02    Address of endpoint
743  * 3    bmAttributes            1       0x02    Endpoint attributes - Bulk
744  * 4    bNumEndpoints           2       0x0040  maximum packet size
745  * 5    bInterval               1       0x00    Interval for polling endpoint
746  *     
747  * DATA FORMAT
748  * 
749  * IN Endpoint
750  * 
751  * The device reserves the first two bytes of data on this endpoint to contain the current
752  * values of the modem and line status registers. In the absence of data, the device 
753  * generates a message consisting of these two status bytes every 40 ms
754  * 
755  * Byte 0: Modem Status
756  * 
757  * Offset       Description
758  * B0   Reserved - must be 1
759  * B1   Reserved - must be 0
760  * B2   Reserved - must be 0
761  * B3   Reserved - must be 0
762  * B4   Clear to Send (CTS)
763  * B5   Data Set Ready (DSR)
764  * B6   Ring Indicator (RI)
765  * B7   Receive Line Signal Detect (RLSD)
766  * 
767  * Byte 1: Line Status
768  * 
769  * Offset       Description
770  * B0   Data Ready (DR)
771  * B1   Overrun Error (OE)
772  * B2   Parity Error (PE)
773  * B3   Framing Error (FE)
774  * B4   Break Interrupt (BI)
775  * B5   Transmitter Holding Register (THRE)
776  * B6   Transmitter Empty (TEMT)
777  * B7   Error in RCVR FIFO
778  * 
779  */
780 #define FTDI_RS0_CTS    (1 << 4)
781 #define FTDI_RS0_DSR    (1 << 5)
782 #define FTDI_RS0_RI     (1 << 6)
783 #define FTDI_RS0_RLSD   (1 << 7)
784
785 #define FTDI_RS_DR  1
786 #define FTDI_RS_OE (1<<1)
787 #define FTDI_RS_PE (1<<2)
788 #define FTDI_RS_FE (1<<3)
789 #define FTDI_RS_BI (1<<4)
790 #define FTDI_RS_THRE (1<<5)
791 #define FTDI_RS_TEMT (1<<6)
792 #define FTDI_RS_FIFO  (1<<7)
793
794 /*
795  * OUT Endpoint
796  * 
797  * This device reserves the first bytes of data on this endpoint contain the length
798  * and port identifier of the message. For the FTDI USB Serial converter the port 
799  * identifier is always 1.
800  * 
801  * Byte 0: Line Status
802  * 
803  * Offset       Description
804  * B0   Reserved - must be 1
805  * B1   Reserved - must be 0
806  * B2..7        Length of message - (not including Byte 0)
807  * 
808  */
809