ieee1394: sbp2: fix spindown for PL-3507 and TSB42AA9 firmwares
authorStefan Richter <stefanr@s5r6.in-berlin.de>
Sat, 10 May 2008 22:35:55 +0000 (00:35 +0200)
committerStefan Richter <stefanr@s5r6.in-berlin.de>
Mon, 14 Jul 2008 11:00:18 +0000 (13:00 +0200)
commit3719122a520af2957031859317e74858ab4d3f4b
treea9116fbe4e7046f6a5c743390b41381da2699740
parentffcaade3109c3a4c0a2c601cf2a44d55b4c3af37
ieee1394: sbp2: fix spindown for PL-3507 and TSB42AA9 firmwares

Reported by Tino Keitel:  PL-3507 with firmware from Prolific does not
spin down the disk on START STOP UNIT with power condition = 0 and start
= 0.  It does however work with power condition = 2 or 3.

Also found while investigating this:  DViCO Momobay CX-1 and FX-3A (TI
TSB42AA9/A based) become unresponsive after START STOP UNIT with power
condition = 0 and start = 0.  They stay responsive if power condition is
set when stopping the motor.

Signed-off-by: Stefan Richter <stefanr@s5r6.in-berlin.de>
drivers/ieee1394/sbp2.c
drivers/ieee1394/sbp2.h