[PATCH] hwmon: Fix negative temperature readings in lm77 driver
authorJean Delvare <khali@linux-fr.org>
Mon, 9 Jan 2006 21:43:08 +0000 (22:43 +0100)
committerGreg Kroah-Hartman <gregkh@suse.de>
Mon, 6 Feb 2006 20:02:14 +0000 (12:02 -0800)
Fix negative temperature readings in lm77 driver.

Signed-off-by: Jean Delvare <khali@linux-fr.org>
Acked-by: Michael Renzmann <mrenzmann@otaku42.de>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
drivers/hwmon/lm77.c

index a2f420d..df9e02a 100644 (file)
@@ -87,15 +87,15 @@ static struct i2c_driver lm77_driver = {
 
 /* In the temperature registers, the low 3 bits are not part of the
    temperature values; they are the status bits. */
-static inline u16 LM77_TEMP_TO_REG(int temp)
+static inline s16 LM77_TEMP_TO_REG(int temp)
 {
        int ntemp = SENSORS_LIMIT(temp, LM77_TEMP_MIN, LM77_TEMP_MAX);
-       return (u16)((ntemp / 500) * 8);
+       return (ntemp / 500) * 8;
 }
 
-static inline int LM77_TEMP_FROM_REG(u16 reg)
+static inline int LM77_TEMP_FROM_REG(s16 reg)
 {
-       return ((int)reg / 8) * 500;
+       return (reg / 8) * 500;
 }
 
 /* sysfs stuff */