libata: track spindown status and skip spindown_compat if possible
[safe/jmp/linux-2.6] / drivers / ata / libata-scsi.c
index 07b5a3d..b6a1de8 100644 (file)
@@ -967,6 +967,7 @@ static unsigned int ata_scsi_start_stop_xlat(struct ata_queued_cmd *qc)
                 * for more info.
                 */
                if (ata_spindown_compat &&
+                   (qc->dev->flags & ATA_DFLAG_SPUNDOWN) &&
                    (system_state == SYSTEM_HALT ||
                     system_state == SYSTEM_POWER_OFF)) {
                        static unsigned long warned = 0;
@@ -1394,6 +1395,14 @@ static void ata_scsi_qc_complete(struct ata_queued_cmd *qc)
                }
        }
 
+       /* XXX: track spindown state for spindown_compat */
+       if (unlikely(qc->tf.command == ATA_CMD_STANDBY ||
+                    qc->tf.command == ATA_CMD_STANDBYNOW1))
+               qc->dev->flags |= ATA_DFLAG_SPUNDOWN;
+       else if (likely(system_state != SYSTEM_HALT &&
+                       system_state != SYSTEM_POWER_OFF))
+               qc->dev->flags &= ~ATA_DFLAG_SPUNDOWN;
+
        if (need_sense && !ap->ops->error_handler)